D.W. FEARN
VT-1 &
VT-2 Microphone Preamplifers
33
Third Stage
The ar
m of the Attenuation potentiometer feeds the grid of the third stage (a 6072A), which
also operates Class A wit
h a g
ain of approximately 30. This stage is capacitively-coupled to
the grid of the output stage through a polystyrene capacitor.
Output St
age
The output st
ag
e operates as a cathode follower, presenting a comparitively low output
impedance (approximately 800 ohms). The cathode output is coupled through a proprietary
polypropylene capacitor to the primary of the output transformer. This is a custom Jensen
transf
or
mer and is capable of low distortion output at levels exceeding +24dBm.
VU
Meter and Meter Amplifier
A two-stage IC operational amplifier is used to isolate the VU meter from the VT-2 output. An
output sample is derived from th secondary of the output transformer. The VU meter ampli-
fier and -
1
2 volt regulator are constructed on a printed circuit board mounted above the main
chassis.
The meter and meter amplifier may be totally disconnected from the circuit by the Meter
switch. The meter calibrationis set with a 20-turn trimmer potentiometer. Reference level (0
VU) can be set fr
om -20 to o
ver +20dBm. The level indictor is a custom true VU meter con-
forming to ASA Standard C16.5-1954.
P
ower Supplies
Primary power from the AC mains is connected to the VT-1/VT-2 through a standard IEC
power input connector. The Power switch energizes all four power supplies. A fuse, accessi-
ble on t
he r
ear panel, protects the VT-1/VT-2. The Pilot lamp is a type 1819 bulb, operated
f
ar below its rated voltage of 28. The life of the bulb is lengthened, and the light output is
mor
e compatible with other modern studio equipment. The power transformer is a toroidal
unit custom-made for the VT-1/VT-2 and has primary taps for 100, 120, or 220-240 volt oper-
ation. The VT-2 may be rewired for different mains voltages.